CoriolisMaster Series of Coriolis Mass Flowmeters
ABB’s CoriolisMaster series delivers world-class coriolis mass flowmeters for a wide variety of applications.
Wide range of meter sizes provide precise measurement of massflow, volume flow, density, temperature and concentration. ABB's CoriolisMaster series has a history of success in a wide variety of industries and applications. With innovations like sensor memory, easy set-up and no up or downstream piping requirements - they save time and money during installation, commissioning and maintenance.
Benefits of using ABB’s CoriolisMaster flowmeters:
− Save cost by making several measurements with one device
− Reduce flowmeter maintenance by up to 90 %
− No mechanical wear and minimize installation issues
− Save up to 25 % on pump power
− Save critical installation space
Our Offering
1. One of the most cost saving meters on the market today with the most innovative new transmitter system - save on installation and handling, pump power and spares cost with this new class-leading Coriolis mass flowmeter.
FCB400 series
CoriolisMaster FCB430 and FCB450
![](http://abbimageservice.cloudapp.net/public/v2/fa86b10b-0a8b-4ba2-ae35-e455e4092b59/sitefinity_32.jpg?target=http%3a%2f%2fabbib.cloudapp.net%2fpublic%2fv2%2ffa86b10b-0a8b-4ba2-ae35-e455e4092b59%2fsitefinity_32.jpg%3fcrop%3d0%2c0%2c0%2c0%26width%3d0%26height%3d0&key=9dcca932f17e2a065f89a22ed373c7e8)
Data
General specifications:
- Nominal sizes / measuring ranges
– DN 15 (1/2 in.) / 0 to 8,000 kg/h (17,637 lb/h)
– DN 25 (1 in.) / 0 to 35,000 kg/h (77,162 lb/h)
– DN 50 (2 in.) / 0 to 90,000 kg/h (198,416 lb/h)
– DN 80 (3 in.) / 0 to 250,000 kg/h (551,156 lb/h)
– DN 100 (4 in.) / 0 to 520,000 kg/h (1,146,404 lb/h)
– DN 150 (6 in.) / 0 to 860,000 kg/h (1,895,975 lb/h) - Ex approvals
– ATEX zone 0/1/2, cFMus Div 1/2 and zone 0/1/2 - Wetted materials
– 1.4404 / 1.4435 (316L) or Hasteloy C - Accuracy for liquids
FCB430
– Mass and volume: 0.4 % o. r. / 0.25 % o. r. / 0.2 % o. r.
– Density: 10 g/l
FCB450
– Mass: 0.15 % o. r. / 0.1 % o. r., volume: 0.15 % o. r.
– Density: 2 g/l or 1 g/l - Measuring medium temperature
FCB430
– -50 to 160 °C (-58 to 320 °F)
FCB450
– -50 to 205 °C (-58 to 400 °F) - Outputs
– 5 modular I/Os
– HART 7.1 - Power supply
– 11 to 30 V DC, 110/230 V AC
2. All the outstanding benefits of the FCB400 series is available as a hygienic version for superb and certified cleanability.
FCH400 series
CoriolisMaster FCH430 and FCH450
![](http://abbimageservice.cloudapp.net/public/v2/6b47b27b-2713-4cbb-90d1-3ce038105d71/sitefinity_32.jpg?target=http%3a%2f%2fabbib.cloudapp.net%2fpublic%2fv2%2f6b47b27b-2713-4cbb-90d1-3ce038105d71%2fsitefinity_32.jpg%3fcrop%3d0%2c0%2c0%2c0%26width%3d0%26height%3d0&key=cd4044bc7c2c83d1d72859a81090ed27)
Data
General specifications:
- Nominal sizes / measuring ranges
– DN 25 (1 in.) / 0 to 35,000 kg/h (77,162 lb/h)
– DN 50 (2 in.) / 0 to 90,000 kg/h (198,416 lb/h)
– DN 80 (3 in.) / 0 to 250,000 kg/h (551,156 lb/h) - Ex approvals
– ATEX zone 0/1/2, cFMus Div 1/2 and zone 0/1/2 - Hygienic approvals
– EHEDG and FDA material compliant - Wetted materials
– 1.4404 / 1.4435 (316L) - Accuracy for liquids
FCH430
– Mass and volume: 0.4 % o. r. / 0.25 % o. r. / 0.2 % o. r.
– Density: 10 g/l
FCH450
– Mass: 0.15 % o. r. / 0.1 % o. r., volume: 0.15 % o. r.
– Density: 2 g/l or 1 g/l - Measuring medium temperature
FCH430
– -50 to 160 °C (-58 to 320 °F)
FCH450
– -50 to 205 °C (-58 to 400 °F) - Outputs
– 5 modular I/Os
– HART 7.1 - Power supply
– 11 to 30 V DC, 110/230 V AC
3. Offering high speed RS485 Modbus communication and 2 digital outputs, ideal for integration into systems and providing accurate high speed and density measurement.
FCB100 series
CoriolisMaster FCB130 and FCB150
![](http://abbimageservice.cloudapp.net/public/v2/004db6e9-71c6-457d-ad5f-d6508d2de3d3/sitefinity_32.jpg?target=http%3a%2f%2fabbib.cloudapp.net%2fpublic%2fv2%2f004db6e9-71c6-457d-ad5f-d6508d2de3d3%2fsitefinity_32.jpg%3fcrop%3d0%2c0%2c0%2c0%26width%3d0%26height%3d0&key=946db336973e20b448da428abfe5700b)
Data
General specifications:
- Nominal sizes / measuring ranges
– DN 15 (1/2 in.) / 0 to 8,000 kg/h (17,637 lb/h)
– DN 25 (1 in.) / 0 to 35,000 kg/h (77,162 lb/h)
– DN 50 (2 in.) / 0 to 90,000 kg/h (198,416 lb/h)
– DN 80 (3 in.) / 0 to 250,000 kg/h (551,156 lb/h)
– DN 100 (4 in.) / 0 to 520,000 kg/h (1,146,404 lb/h)
– DN 150 (6 in.) / 0 to 860,000 kg/h (1,895,975 lb/h) - Ex approvals
– ATEX zone 0/1/2, cFMus Div 1/2 and zone 0/1/2 - Wetted materials
– 1.4404 / 1.4435 (316L) or Hasteloy C - Accuracy for liquids
FCB130
– Mass and volume: 0.4 % o. r. / 0.25 % o. r.
– Density: 10 g/l
FCB150
– Mass: 0.15 % o. r. / 0.1 % o. r., volume: 0.15 % o. r.
– Density: 2 g/l or 1 g/l - Measuring medium temperature
FCB130
– -50 to 160 °C (-58 to 320 °F)
FCB150
– -50 to 205 °C (-58 to 400 °F) - Outputs
– 2 digital out (pulse, frequency, contact)
– Modbus - Power supply
– 11 to 30 V DC
4. Offering the hygienic sensor with EHEDG approval with high speed RS485 Modbus communication and 2 digital outputs, ideal for integration into systems and providing accurate high speed and density measurement.
FCH100 series
CoriolisMaster FCH130 and FCH150
![](http://abbimageservice.cloudapp.net/public/v2/0af83abf-8f46-4901-9919-f693d0cfc444/sitefinity_32.jpg?target=http%3a%2f%2fabbib.cloudapp.net%2fpublic%2fv2%2f0af83abf-8f46-4901-9919-f693d0cfc444%2fsitefinity_32.jpg%3fcrop%3d0%2c0%2c0%2c0%26width%3d0%26height%3d0&key=672ebb05cfe22b8c1906a2d647d3206f)
Data
General specifications:
- Nominal sizes / measuring ranges
– DN 25 (1 in.) / 0 to 35,000 kg/h (77,162 lb/h)
– DN 50 (2 in.) / 0 to 90,000 kg/h (198,416 lb/h)
– DN 80 (3 in.) / 0 to 250,000 kg/h (551,156 lb/h) - Ex approvals
– ATEX zone 0/1/2, cFMus Div 1/2 and zone 0/1/2 - Wetted materials
– 1.4404 / 1.4435 (316L) - Accuracy for liquids
FCH130
– Mass and volume: 0.4 % o. r. / 0.25 % o. r.
– Density: 10 g/l
FCH150
– Mass: 0.15 % o. r. / 0.1 % o. r., volume: 0.15 % o. r.
– Density: 2 g/l or 1 g/l - Measuring medium temperature
FCH130
– -50 to 160 °C (-58 to 320 °F)
FCH150
– -50 to 205 °C (-58 to 400 °F) - Outputs
– 2 digital out (pulse, frequency, contact)
– Modbus - Power supply
– 11 to 30 V DC
5. Precision measurement for extremly low flow rates and line sizes.
FCM2000-MS2
CoriolisMaster FCM2000-MS2
![](http://abbimageservice.cloudapp.net/public/v2/ea136505-ce2b-4aa9-a1d4-38f6dbb6f349/sitefinity_32.jpg?target=http%3a%2f%2fabbib.cloudapp.net%2fpublic%2fv2%2fea136505-ce2b-4aa9-a1d4-38f6dbb6f349%2fsitefinity_32.jpg%3fcrop%3d0%2c0%2c0%2c0%26width%3d0%26height%3d0&key=a17052c00af3b968fe5bba841d31e849)
Data
General specifications:
- Nominal sizes / measuring ranges
– DN 1.5 (1/16 in.) / 0 to 65 kg/h (143 lb/h)
– DN 3 (1/10 in.) / 0 to 250 kg/h (551 lb/h)
– DN 6 (1/4 in.) / 0 to 1,000 kg/h (2,205 lb/h) - Ex approvals
– ATEX zone 0/1/2, cFMus Div 1/2 and zone 0/1/2, NEPSI 0/1/2 - Wetted materials
– 1.4404 / 1.4435 (316L) or Hasteloy C - Maximum process pressure
– up to 500 bar (7250 psi) for details and restrictions see data sheet - Accuracy for liquids
– Massflow: 0.4 % o. r. / 0.25 % o. r. / 0.15 % o. r. / 0.1 % o. r.
– Density: 4 g/l or 1 g/l - Measuring medium temperature
– -50 to 180 °C (-58 to 356 °F) - Outputs
– 2 current outputs, 1 pulse, 1 contact out/in - Power supply
– 24 V AC/DC, 110/230 V AC
6. One of the most cost saving meters on the market today - save on installation, pump power with this Coriolis mass flowmeter.
FCB300 series
CoriolisMaster FCB330 and FCB350
![](http://abbimageservice.cloudapp.net/public/v2/51bbe1b0-08d3-42b8-9278-96dd8a0bd8b7/sitefinity_32.jpg?target=http%3a%2f%2fabbib.cloudapp.net%2fpublic%2fv2%2f51bbe1b0-08d3-42b8-9278-96dd8a0bd8b7%2fsitefinity_32.jpg%3fcrop%3d0%2c0%2c0%2c0%26width%3d0%26height%3d0&key=4d7b3ff390b187d5e2e1000146876624)
Data
General specifications:
- Nominal sizes / measuring ranges
– DN 15 (1/2 in.) / 0 to 8,000 kg/h (17,637 lb/h)
– DN 25 (1 in.) / 0 to 35,000 kg/h (77,162 lb/h)
– DN 50 (2 in.) / 0 to 90,000 kg/h (198,416 lb/h)
– DN 80 (3 in.) / 0 to 250,000 kg/h (551,156 lb/h)
– DN 100 (4 in.) / 0 to 520,000 kg/h (1,146,404 lb/h)
– DN 150 (6 in.) / 0 to 860,000 kg/h (1,895,975 lb/h) - Ex approvals
– ATEX zone 0/1/2, cFMus Div 1/2 and zone 0/1/2, NEPSI 0/1/2 - Marine approval
– DNV - GL - Wetted materials
– 1.4404 / 1.4435 (316L) or Hasteloy C - Accuracy for liquids
FCB330
– Mass and volume: 0.4 % o. r. / 0.25 % o. r.
– Density: 10 g/l
FCB350
– Mass: 0.15 % o. r. / 0.1 % o. r., volume: 0.15 % o. r.
– Density: 2 g/l or 1 g/l - Measuring medium temperature
FCB330
– -50 to 160 °C (-58 to 320 °F)
FCB350
– -50 to 205 °C (-58 to 400 °F) - Outputs
– 2 current outputs, 1 pulse, 1 contact out/in
– HART - Power supply
– 24 V AC/DC, 110/230 V AC
7. All the outstanding benefits of the FCB300 series ia available as a hygienic version for superb and certified cleanability.
FCH300 series
CoriolisMaster FCH330 and FCH350
![](http://abbimageservice.cloudapp.net/public/v2/b81e5f8b-a3f3-428e-a128-6a042f52d304/sitefinity_32.jpg?target=http%3a%2f%2fabbib.cloudapp.net%2fpublic%2fv2%2fb81e5f8b-a3f3-428e-a128-6a042f52d304%2fsitefinity_32.jpg%3fcrop%3d0%2c0%2c0%2c0%26width%3d0%26height%3d0&key=3a63870a1c068858fe5eeb17f25c2283)
Data
General specifications:
- Nominal sizes / measuring ranges
– DN 25 (1 in.) / 0 to 35,000 kg/h (77,162 lb/h)
– DN 50 (2 in.) / 0 to 90,000 kg/h (198,416 lb/h)
– DN 80 (3 in.) / 0 to 250,000 kg/h (551,156 lb/h) - Ex approvals
– ATEX zone 0/1/2, cFMus Div 1/2 and zone 0/1/2, NEPSI 0/1/2 - Hygienic approvals
– EHEDG and FDA material compliant - Wetted materials
– 1.4404 / 1.4435 (316L) - Accuracy for liquids
FCH330
– Mass and volume: 0.4 % o. r. / 0.25 % o. r.
– Density: 10 g/l
FCH350
– Mass: 0.15 % o. r. / 0.1 % o. r., volume: 0.15 % o. r.
– Density: 2 g/l or 1 g/l - Measuring medium temperature
FCH330
– -50 to 160 °C (-58 to 320 °F)
FCH350
– -50 to 205 °C (-58 to 400 °F) - Outputs
– 2 current outputs, 1 pulse, 1 contact out/in
– HART - Power supply
– 24 V AC/DC, 110/230 V AC
8. Unique S-shape tube and modular design for tough measurement requirements.
FCM2000-MC2
![](http://abbimageservice.cloudapp.net/public/v2/824d8142-120c-4989-886f-636714d838df/sitefinity_32.jpg?target=http%3a%2f%2fabbib.cloudapp.net%2fpublic%2fv2%2f824d8142-120c-4989-886f-636714d838df%2fsitefinity_32.jpg%3fcrop%3d0%2c0%2c0%2c0%26width%3d0%26height%3d0&key=9d025e192c348dfa5c4592d8bc86388a)
Data
General specifications:
- Nominal sizes / measuring ranges
– DN 20 (3/4 in.) / 0 to 6,000 kg/h (13,227 lb/h)
– DN 25 (1 in.) / 0 to 9,600 kg/h (21,146 lb/h)
– DN 40 (1.5 in.) / 0 to 28,500 kg/h (62,832 lb/h)
– DN 50 (2 in.) / 0 to 55,200 kg/h (121,695 lb/h)
– DN 80 (3 in.) / 0 to 147,600 kg/h (325,402 lb/h)
– DN 100 (4 in.) / 0 to 249,600 kg/h (550,274 lb/h)
– DN 150 (6 in.) / 0 to 660,000 kg/h (1,455,051 lb/h) - Ex approvals
– ATEX zone 0/1/2, cFMus Div 1/2 and zone 0/1/2, NEPSI 0/1/2 - Wetted materials
– 1.4571 (316Ti) or 1.4404 / 1.4435 (316L) or Hasteloy C - Accuracy for liquids
– Massflow: 0.4 % o. r. / 0.25 % o. r. / 0.15 % o. r. / 0.1 % o. r.
– Density: 4 g/l or 1 g/l - Measuring medium temperature
– -50 to 200 °C (-58 to 396 °F) - Outputs
– 2 current outputs, 1 pulse, 1 contact out/in - Power supply
– 24 V AC/DC, 110/230 V AC
1. Data sheet - CoriolisMaster FCB430, FCB450, FCH430, FCH450 - Coriolis mass flowmeter
7. Data sheet - CoriolisMaster FCB330, FCB350, FCH330, FCH350 - Coriolis mass flowmeter
Người gửi / điện thoại
CONTACT
HOP VIET ENG CO., LTD
Office: 217A Quach Dinh Bao Str, Phu Thanh Wad, Tan Phu Dist, HCMC, VietNam
Add: 15 Le Thiet Str, Phu Tho Hoa Ward, Tan Phu Dist, HCMC, Vietnam
Tel: (+84 28) 6267 5677 - Fax: (+84 28) 6265 5066